DFPH093 (FHP12-SHC09)
Rev. 1.2 [1/05]
JOB NAME: _____________________________________ LOCATION: _______________________________________
PURCHASER: _____________________________________________________________________________________
ENGINEER:_______________________________________________________________________________________
SUBMITTED TO: _________________________________ FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ]
SUBMITTED BY: _________________________________ DATE: ___________________________________________
UNIT DESIGNATION: SCHEDULE #: _______________ MODEL #: ________________________________________
CAPACITIES:
Cooling
Heating
9,500 Btu
9,000 Btu
5,300 Btu
– High
– Low
Indoor Design Temp ºF DB/WB
Cooling
Heating
80/67
70/57
Outdoor Design Temp ºF DB/WB
Cooling
Heating
95/75
47/43
17/15
– High
– Low
26”
EER
SEER
HSPF
10.0
10.5
7.1
47”
INDOOR UNIT:
Power Supply
Max. Fuse Size
Min. Ampacity
Max. Fuse Size
Min. Ampacity
Sound
101/2”
208/230/1/60
15 Amps (w/o electric heat)
0.8 Amps (w/o electric heat)
20 Amps (w/3kw electric heat)
17.1 Amps (w/3kw electric heat)
48.6 dBa
Weight
110 Lbs
OUTDOOR UNIT:
Power Supply
Max. Fuse Size
Min. Ampacity
Sound
208/230/1/60
15 Amps
6.1 Amps
58.0 dBa
90 Lbs
Weight
REFRIGERANT PIPING:
Max. Lift
35 Ft
Max. Length
Liquid (OD)
Suction (OD)
100 Ft
1/4 In
1/2 In
STANDARD FEATURES:
• Five-year compressor/One-year parts warranty
• Auto restart following a power outage
• Anti-Short Cycle protection
• Fresh Air knockouts
• Side Discharge/Low profile condenser
• Fan Purge
• Crank Case Heater
• Manual Reset High Pressure Switch
• “Duratec” Performance Package For Compressor Protection
- Suction Accumulator
- Filter Dryer
- Loss Of Charge Switch
Enviromaster International LLC
Rome, New York, USA
EMI ENGINEERING SUBMITTAL DFPH093 (FHP12-SHC09)
are selected; fan operation of auto (cycling), high and low (constant), auto fan operation automatically selects fan
speed according to heating or cooling demand; dry mode operates cooling and electric heat simultaneously to
remove humidity, optional electric heat must be selected; test operation allows ease of testing after installation (all
timers are eliminated); non-volatile back-up memory, control settings are maintained for an indefinite period during
a power outage, when power is restored the equipment will resume operation after a three-minute compressor time
delay; optional hand held infra-red controller. The control voltage between the indoor unit and the outdoor unit shall
be 24 Volts A.C. The 24 Volts shall be generated from the indoor unit’s 24 Volt 40VA transformer.
PART SIX “OUTDOOR UNIT”
The outdoor unit shall be completely factory assembled, piped and wired. The cabinet shall be fabricated of G60
galvannealed steel, finished in “off-white” with corrosion inhibiting polyester powder-coated paint. The unit shall be
furnished with one (1) direct drive, propeller type fan arranged for horizontal discharge. The motor shall have inherent
protection, be of the permanently lubricated type, and resiliently mounted for quiet operation. The fan shall be provided
with a guard to prevent contact with moving parts. The compressor shall be of the high-performance rotary type with
Duratec package which consists of an oversized accumulator, factory installed solid core filter drier and thermal
overloads. The compressor shall be mounted so as to avoid the transmission of vibration. The refrigeration system
shall be equipped with a loss of charge switch, and have the capability to operate with a maximum height difference
of 35 feet and overall refrigerant tubing length of 100 feet between indoor and outdoor sections without the need for
line size changes or additional oil. The condenser coil shall be of nonferrous construction with louvered fins bonded
to rifled copper tubing. The unit shall be controlled by the microprocessor located in the indoor matching unit. The
heating expansion is controlled by a TXV in the outdoor unit. The unit electrical power shall be 208/230 Volts, 1 phase,
60 Hertz. The system shall be capable of satisfactory operation within voltage limits of 208/230 Volts +/- 10%.
PART SEVEN “OPTIONAL EQUIPMENT”
• Hand Held Infrared Remote Controller – used to command the unit-mounted controls.
• 24V Wall Thermostat Control – anti-short cycle compressor protection; fan purge, fan remains on for 60 seconds
after heat/cool call is dropped for improved efficiency; integral heating relay ensures that the fan operates whenever
electric heat is energized; two stage heating capable when matched up with an EMI heat pump and an appropriate
two stage thermostat.
• 3KW Electric Heat – shall be factory installed; automatic reset high temperature cutout and redundant high
temperature fuse link.
• Single-Stage hydronic heating coil (one row type) w/sweat connections.
• Internal Condensate Pump – shall be field installed or factory installed and shall have 12 ft of head.
• Low Ambient Control – shall consist of a fan cycle switch and a lock-out relay, field installed.
• Hard Start – shall be field installed.
• Sea Coast Style Coated Coils – shall be factory installed; coating shall protect against corrosion due to acids,
solvents and salt.
5780 Success Drive, Rome, NY 13440
Phone: 1-800-228-9364
FAX: 1-800-232-9364
Email: [email protected]
Enviromaster International LLC
Rome, New York, USA
|