EMI DFPH093 FHP12 SHC09 User Manual

DFPH093 (FHP12-SHC09)  
Rev. 1.2 [1/05]  
JOB NAME: _____________________________________ LOCATION: _______________________________________  
PURCHASER: _____________________________________________________________________________________  
ENGINEER:_______________________________________________________________________________________  
SUBMITTED TO: _________________________________ FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ]  
SUBMITTED BY: _________________________________ DATE: ___________________________________________  
UNIT DESIGNATION: SCHEDULE #: _______________ MODEL #: ________________________________________  
CAPACITIES:  
Cooling  
Heating  
9,500 Btu  
9,000 Btu  
5,300 Btu  
– High  
– Low  
Indoor Design Temp ºF DB/WB  
Cooling  
Heating  
80/67  
70/57  
Outdoor Design Temp ºF DB/WB  
Cooling  
Heating  
95/75  
47/43  
17/15  
– High  
– Low  
26”  
EER  
SEER  
HSPF  
10.0  
10.5  
7.1  
47”  
INDOOR UNIT:  
Power Supply  
Max. Fuse Size  
Min. Ampacity  
Max. Fuse Size  
Min. Ampacity  
Sound  
101/2”  
208/230/1/60  
15 Amps (w/o electric heat)  
0.8 Amps (w/o electric heat)  
20 Amps (w/3kw electric heat)  
17.1 Amps (w/3kw electric heat)  
48.6 dBa  
Weight  
110 Lbs  
OUTDOOR UNIT:  
Power Supply  
Max. Fuse Size  
Min. Ampacity  
Sound  
208/230/1/60  
15 Amps  
6.1 Amps  
58.0 dBa  
90 Lbs  
Weight  
REFRIGERANT PIPING:  
Max. Lift  
35 Ft  
Max. Length  
Liquid (OD)  
Suction (OD)  
100 Ft  
1/4 In  
1/2 In  
STANDARD FEATURES:  
• Five-year compressor/One-year parts warranty  
• Auto restart following a power outage  
• Anti-Short Cycle protection  
• Fresh Air knockouts  
• Side Discharge/Low profile condenser  
• Fan Purge  
• Crank Case Heater  
• Manual Reset High Pressure Switch  
• “Duratec” Performance Package For Compressor Protection  
- Suction Accumulator  
- Filter Dryer  
- Loss Of Charge Switch  
Enviromaster International LLC  
Rome, New York, USA  
EMI ENGINEERING SUBMITTAL DFPH093 (FHP12-SHC09)  
are selected; fan operation of auto (cycling), high and low (constant), auto fan operation automatically selects fan  
speed according to heating or cooling demand; dry mode operates cooling and electric heat simultaneously to  
remove humidity, optional electric heat must be selected; test operation allows ease of testing after installation (all  
timers are eliminated); non-volatile back-up memory, control settings are maintained for an indefinite period during  
a power outage, when power is restored the equipment will resume operation after a three-minute compressor time  
delay; optional hand held infra-red controller. The control voltage between the indoor unit and the outdoor unit shall  
be 24 Volts A.C. The 24 Volts shall be generated from the indoor unit’s 24 Volt 40VA transformer.  
PART SIX “OUTDOOR UNIT”  
The outdoor unit shall be completely factory assembled, piped and wired. The cabinet shall be fabricated of G60  
galvannealed steel, finished in “off-white” with corrosion inhibiting polyester powder-coated paint. The unit shall be  
furnished with one (1) direct drive, propeller type fan arranged for horizontal discharge. The motor shall have inherent  
protection, be of the permanently lubricated type, and resiliently mounted for quiet operation. The fan shall be provided  
with a guard to prevent contact with moving parts. The compressor shall be of the high-performance rotary type with  
Duratec package which consists of an oversized accumulator, factory installed solid core filter drier and thermal  
overloads. The compressor shall be mounted so as to avoid the transmission of vibration. The refrigeration system  
shall be equipped with a loss of charge switch, and have the capability to operate with a maximum height difference  
of 35 feet and overall refrigerant tubing length of 100 feet between indoor and outdoor sections without the need for  
line size changes or additional oil. The condenser coil shall be of nonferrous construction with louvered fins bonded  
to rifled copper tubing. The unit shall be controlled by the microprocessor located in the indoor matching unit. The  
heating expansion is controlled by a TXV in the outdoor unit. The unit electrical power shall be 208/230 Volts, 1 phase,  
60 Hertz. The system shall be capable of satisfactory operation within voltage limits of 208/230 Volts +/- 10%.  
PART SEVEN “OPTIONAL EQUIPMENT”  
• Hand Held Infrared Remote Controller – used to command the unit-mounted controls.  
• 24V Wall Thermostat Control – anti-short cycle compressor protection; fan purge, fan remains on for 60 seconds  
after heat/cool call is dropped for improved efficiency; integral heating relay ensures that the fan operates whenever  
electric heat is energized; two stage heating capable when matched up with an EMI heat pump and an appropriate  
two stage thermostat.  
• 3KW Electric Heat – shall be factory installed; automatic reset high temperature cutout and redundant high  
temperature fuse link.  
• Single-Stage hydronic heating coil (one row type) w/sweat connections.  
• Internal Condensate Pump – shall be field installed or factory installed and shall have 12 ft of head.  
• Low Ambient Control – shall consist of a fan cycle switch and a lock-out relay, field installed.  
• Hard Start – shall be field installed.  
• Sea Coast Style Coated Coils – shall be factory installed; coating shall protect against corrosion due to acids,  
solvents and salt.  
5780 Success Drive, Rome, NY 13440  
Phone: 1-800-228-9364  
FAX: 1-800-232-9364  
Enviromaster International LLC  
Rome, New York, USA  

AllerAir 9640 User Manual
Brother MFC9750 User Manual
Carrier 09DK054 084 User Manual
Carrier 48HG14 28 User Manual
Danby dac10007ee User Manual
Epson STYLUS NX410 User Manual
Friedrich Air Conditioner US10B10A User Manual
Heat Controller Inc Air Conditioner EKTH User Manual
Heat Controller Inc Air Conditioner MMH18DA 1 User Manual
Hollywood Sport Rider HR1000 User Manual